Circulating units are used on the primary circuit of solar heating systems to control the temperature of the hot water storage. The unit gathered the Circulating Pump; Hose Bibs for Filling and Draining; Air Scoop and Air Vent; Pressure Relief Valve; Pressure Gauge in together.

 

1. Willo-Solar circulating pump
2. Pressure Relief Valve
3. Hose Bibs for filling and Draining
4. Pressure Gauge
5. Flow meter
6. Air Scoop & Air Vent
7. Return temperature gauge ( Chose Use)
8. Pre formed insulation shell
9. Shut-off and check valve (on the back side of the temperature gauge)
10. Connection kit for expansion vessel (optional)
11. ¾ plug (to be used if no expansion vessel is installed)


High temperature expansion tank for solar heating systems. Compatible with glycol mixture.
Max. percentage of glycol: 50%
Max. working pressure: 150 psi.
Working temperature range: 32 – 2500F. Max.
Diaphragm temperature: 2150F. Pre-charged.
Pressure: 35 psi.

 


1. Construction:
Inner Tank: 1.5 – 2.0mm thickness
SUS316 Stainless Stell structure. Outer Shell:
0.5mm thickness imported colour steel and
aluminum-zinc plated steel, coated with
high-tech corrosion resistant layer.

2. Containment:
High Temperature membrane liner.
Rating 212 F continuous. All penetrations in and
Out of the tank from the top, except for the
Overflow.

3. Insulation: 50 – 60 mm import polyurethane integral foaming superior heat preservation.

4. SUS316L or 30428 Food Grade Stainless Steel led by argon are superior water and quality drinkable.
5. Corrosion inhibitor is added to the inside of the tank to protect the exterior of copper heat exchangers.

6. Designs for Open or closed loop systems.

System Controllers

Low Pressure Controller

1. Power supply: 220V AC Power consumption: =6WM
2. Accuracy of temperature measuring: ±2°C
3. Range of temperature measuring: 0°C-99°C
4. Water level classification: Five classes display
5. Power of controlled booster pump or electric heating wire=500W
6. Power of controlled electric heating: =1500W, Optional: 3000W
7. Action current of electric leakage=10mA/0.1s
8. Electromagnetic valve parameter: DC12V, pressurized or un-pressurized valve are available for selection
9. Operating pressure of pressurized valve: 0.02Mpa-0.8Mpa, suitable for supply water directly.
10. Operating pressure of un-pressurized valve : 0.0Mpa, suitable for water-tank supply or low hydraulic- pressure supply
  • Power on self-test 
  •                          
  • Water temperature preset
  • Water temperature indication
  •                             
  • Water shortage alarming 
  •                                     
  • Temperature-controlled loading
  •                              
  • Timing heating
  •                                                             
  • Low water pressure loading
  •                                 
  • Dry fire prevent
  •                                
  • Water level set
  •                                
  • Water level indication
  •    
  • Full water alarm
  • Water shortage loading 
  •  
  •  Manual water loading
  • Timing water loading  
  •  
  • Compulsive water loading
  • Water quality set 
  •  
  • Pipe warm preservation
  •  
  • Automatic pressurization
  • Auto leakage prevention
  • High-temperature explosion protection
  • Memory on power failure
  • low pressure controller

    High Pressure Controller

    Key Function
    1.      Preset of water temperature: Heating temperature scope can be preset at 30°C-80°C.
    2.      Temperature indication of water tank: showing the accurate temperature of water tank
    3.      Temperature indication of solar collector: showing the accurate temperature of solar collector
    4.      Manual controlling: it could manually start heating, circulating, temperature preserving at the situation of two patterns.

    high pressure controller

    NEW PRESSURIZED SPLIT CONTROLLER

    Technical Indicators 1. Power supply: 220VAC   Power consumption: 5W 2. Temperature measuring precision: ±2°C
    3. Temperature measuring scope: 0-99°C
    4. Power of controllable circulation pump: 500W
    5. Power of controllable electric heating: 1500W Optional: 3000W
    6. Action current of electric leakage=10ma/0.1S 

  • Indication of water temperature Real water temperature inside the water tank and solar collector is shown at the same time
  • Heating up-limited it means off the heating automatically when manual or constant heating to up the temperature
  • Heating bottom-limited it means open the heating automatically when the temperature declines to the line at the basis of starting constant heating
  • Temperature difference up-limited It can set temperature of up-limited at 5°C-60°C
  • Temperature difference bottom-limited It can set temperature of bottom-limited at 3°C-60°C
  • Timing heating You could set three times of the function “timing heating” everyday, the time could be precise minute, the temperature scope can be set at 30°C-80°C. Just set the time for “24:00” if you want to shut-off one time of timing heating.
  • Constant heating After starting the function of “constant heating”, till the temperature declines to the bottom-limited, then open heating automatically, however when the temperature rises to the up-limited, then off heating automatically.
  • Temperature difference circulation  When the temperature difference between collector and tank is higher than up-limited temperature difference, starting collector circulation; or it will off the collector circulation.
  • ……….AND MANY MORE
    split controller

    Circulating Pump

    This pump is used for forced circulation of liquids in pipe systems. The main fields of application for these pumps are hot water heating and closed industrial circulation systems. Pumps are equipped with a rotary switch in the terminal box to enable manual 3-speed control. At minimum speed the maximum speed is reduced to approx. 40% - 50%.

    Features:
    - Type 15 with Rp 1/2 '' port and G1 '' threads.
    - Zero-hoisting depth 6m, with blocking current-firm engine.
    - Housing from green cast iron.
    - Impeller from polypropylene.
    - Chrome high-grade steel wave with Graphite sliding bearings.
    - Enclosure IP44.
    - All rotating parts are immersed in the fluid being handled.
    - A shaft seal, being subject to wear and tear is not required
    - Fluid lubricates the shaft bearings and act as coolant to bearings and rotor.
    - The pump is completely maintenance free.

    circulating-pump

    Booster Pump

    Product Description Features:
    1) Low noise; This pump adopts shielding assembly (self-cooling and self-lubricating)
    2) Environmentally friendly; The pump body is treated by antiseptic electric spray painting
    3) The back of the pump body has an exhaust hole

    Specifications:
    1) Power: 30W
    2) Voltage: 220-240V
    3) Frequency: 50Hz
    4) Input & outlet diameter: 25mm (1")
    5) Speed: 2, 280rpm
    6) Highest head: 15m
    7) Max. Capacity: 52L/min
    8) Three-speed
    9) Liquid temperature: -10 - 110 `C
    10) Environmental temperature: < 40 `C
    11) System pressure: <10 Bar

    circulating-pump

    Auto Air relief valve

    Safety valve to be used in conjunction with High Pressure split systems

    circulating-pump

    MTD 8 Eskom approved timer

    220 Volt; 50 Hz
    16 Amps
    Battery backup 100 Hour memory back-up
    Timer to be used in conjunction with 2000 W elements

    mtd8

    Magnesium Rod

    To assist against the built-up of scale in areas where the water quality are good
    Two Types available:
    In tank mag.rod for High Pressure direct compact systems
    In tube mag.rod for Low pressure direct compact systems

    mtd8

     